§ 153.284 Characteristics of required quick closing valves.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 153.284, § 153.284 Characteristics of required quick closing valves, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228657
Permanent ID
ys:prov:228657@1
SHA-256
2423e9092e5aba9a090c6e2b728ad239edbf38b13746e1e453946573735e9997

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

A remotely actuated quick closing shutoff valve required by § 153.530(n) must: (a) Be a positive shutoff valve; (b) Be of the fail-closed type that closes on loss of power; (c) Be capable of local manual closing; (d) Close from the time of actuation in 30 seconds or less; and (e) Be equipped with a fusible element that melts at less than 104 °C (approx. 220 °F) and closes the valve.