yourstate.us
46 CFR 153.365

§ 153.365 Liquid overpressurization protection.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 153.365, § 153.365 Liquid overpressurization protection, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228683
Permanent ID
ys:prov:228683@1
SHA-256
01c41b1a09b519eeeb93759589db7ec0cc39e2ab427ca1082dab9f209b788744

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Except as noted in paragraph (b) of this section, a containment system requiring closed or restricted gauging must: (1) Be designed to withstand the maximum pressure that develops during an overfill of the densest cargo endorsed for the containment system; or (2) Have an overflow control system that meets § 153.408; or (3) Meet the requirements specified by the Commandant (CG-ENG). (b) A containment system requiring restricted gauging, except for those cargoes that reference §§ 153.525 or 153.527, may be equipped with a spill valve that: (1) Meets ASTM F 1271 (incorporated by reference, see § 153.4); and (2) Limits the maximum pressure during liquid overfill at a specified cargo loading rate to that which the containment system is able to withstand (see §§ 153.294(b) and 152.977(b)).

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.