46 CFR 153.371
§ 153.371 Minimum relief valve setting for refrigerated cargo tanks.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 153.371, § 153.371 Minimum relief valve setting for refrigerated cargo tanks, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228686
- Permanent ID
ys:prov:228686@1- SHA-256
9885fd0406c06b35aeae783d9bbf13d873e57666ee322e323a58e02c7f141b1f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The relief valve setting for a containment system that carries a refrigerated cargo must at least equal the lesser of:
(a) That in § 153.370; or
(b) 110 percent of the cargo's vapor pressure at the steady state temperature obtained by a full tank of cargo with the refrigeration system operating under ambient conditions described within the definition of a refrigerated tank in § 153.2.