46 CFR 153.406

§ 153.406 Standards for containment systems having required restricted gauges.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 153.406, § 153.406 Standards for containment systems having required restricted gauges, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228690
Permanent ID
ys:prov:228690@1
SHA-256
422ec000df70b7d67cf91105a31d782032732a9f84c431d28e7b1d9b85cffe30

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

When Table 1 requires a cargo's containment system to have a restricted gauge, the containment system must have: (a) A closed gauging system; or (b) A system that has: (1) A restricted gauge (e.g., a sounding tube) with an orifice diameter not exceeding 20 cm (approx. 7.8 in.); (2) A permanently attached gauge cover that is vapor tight when in place; and (3) A venting system that has either: (i) Lock open PV valves; or (ii) Valved bypasses around the PV valves.

Legislative history