46 CFR 154.453
§ 154.453 Failure to meet independent tank type C standards.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.453, § 154.453 Failure to meet independent tank type C standards, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228904
- Permanent ID
ys:prov:228904@1- SHA-256
69dce7621472e9601fb1f729c0b85853ef5971f5fd3e4413dde8fd6706be4811
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
If the Commandant (CG-ENG) determines during plan review, that a tank designed as an independent tank type C fails to meet the standards under § 154.450, § 154.451, and 154.452 and cannot be redesigned to meet those standards, the tank may be redesigned as an independent tank type A or B.
Legislative history