46 CFR 154.459
§ 154.459 General.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.459, § 154.459 General, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228905
- Permanent ID
ys:prov:228905@1- SHA-256
25287233eedc8b1becea569987abc4b1ae09ce0435add2c94655ea3d9db802e7
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each cargo tank must have a secondary barrier that meets Table 3 and except as allowed in Table 3, the hull must not be the secondary barrier.
(b) If the Commandant (CG-ENG) specially approves an integral tank for a design temperature at atmospheric pressure lower than −10 °C (14 °F), the integral tank must have a complete secondary barrier that meets § 154.460.
(c) If the Commandant (CG-ENG) specially approves a semi-membrane tank under the requirements of an independent tank type B, the semi-membrane tank may have a partial secondary barrier specially approved by the Commandant (CG-ENG).
(d) If Table 3 allows the hull to be a secondary barrier, the vessel's hull must:
(1) Meet §§ 154.605 through 154.630; and
(2) Be designed for the stresses resulting from the design temperature.
Table 3—Secondary Barriers for Tanks
Legislative history