§ 154.460 Design criteria.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.460, § 154.460 Design criteria, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228906
- Permanent ID
ys:prov:228906@1- SHA-256
1ab918e1008569f0a7e9ab4d051c45a7e4ecd533e5b8ae0de6319239d734a29b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
At static angles of heel up through 30°, a secondary barrier must
(a) If a complete secondary barrier is required in § 154.459, hold all of the liquid cargo in the cargo tank for at least 15 days under the dynamic loads in § 154.409(e);
(b) If a partial secondary barrier is permitted in § 154.459, hold any leakage of liquid cargo corresponding to the extent of failure under § 154.448(a) after initial detection or primary barrier leak for at least 15 days under the dynamic loads in § 154.409(e);
(c) If the primary barrier fails, prevent the temperature of the vessel's structure from falling below the minimum allowable service temperature of the steel; and
(d) Be designed so that a cargo tank failure does not cause a failure in the secondary barrier.