46 CFR 154.530
§ 154.530 Valves: Cargo tank MARVS 69 kPa gauge (10 psig) or lower.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.530, § 154.530 Valves: Cargo tank MARVS 69 kPa gauge (10 psig) or lower, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228926
- Permanent ID
ys:prov:228926@1- SHA-256
a11f69705b479e3cee0d18d9bdcf82e3fa256cad2b362e73ca023f48eb838034
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Except those connections for tank safety relief valves and for liquid level gauging devices other than those under §§ 154.536 and 154.1310, liquid and vapor connections on a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have shut-off valves that—
(1) Are located as close to the tank as practical;
(2) Are capable of local manual operation; and
(3) May be remotely controlled.
(b) The cargo piping system for a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have at least one remotely controlled quick-closing shut-off valve for closing liquid and vapor piping between vessel and shore that meets §§ 154.540 and 154.544.