46 CFR 154.703
§ 154.703 Methane (LNG).
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.703, § 154.703 Methane (LNG), United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228955
- Permanent ID
ys:prov:228955@1- SHA-256
67f22d71ae95435bed14b65e09b46c241d5b0b447d40aca719669097390d7a5d
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Unless a cargo tank carrying methane (LNG) can withstand the pressure build up due to boil-off for 21 days, the pressure in the cargo tank must be maintained below the set pressure of the safety relief valve for at least 21 days by:
(a) A refrigeration system that meets § 154.702;
(b) A waste heat or catalytic furnace that burns boil-off gas, and:
(1) Maintains the stack exhaust temperature below 535 °C (995 °F);
(2) Exhibits no visible flame; and
(3) Is specially approved by the Commandant (CG-OES);
(c) Boilers, inert gas generators, and combustion engines in the main propelling machinery space that use boil-off gas as fuel; or
(d) Equipment for services, other than those under paragraph (c) of this section, that use boil-off gas as fuel and that are located:
(1) In the main propelling machinery space; or
(2) a space specially approved by the Commandant (CG-OES).
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.