yourstate.us
46 CFR 154.709

§ 154.709 Cargo boil-off as fuel: Gas detection equipment.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 154.709, § 154.709 Cargo boil-off as fuel: Gas detection equipment, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228960
Permanent ID
ys:prov:228960@1
SHA-256
4db832fdc98dd4f3308197597e6663b5269f5b5f797cb529573f94f139ae3f6e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) The continuous gas detection system required under § 154.706(a)(2) and (b) must: (1) Meet § 154.1350(c), (d), and (j) through (s); and (2) Have a device that: (i) Activates an audible and visual alarm at the machinery control station and in the wheelhouse if the methane concentration reaches 1.5 percent by volume; and (ii) Closes the master gas fuel valve required under § 154.708(c) before the methane concentration reaches 3 percent by volume. (b) The number and arrangement of gas sampling points must be specially approved by the Commandant (CG-OES).

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.