46 CFR 154.1005
§ 154.1005 Equipment approval.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 154.1005, § 154.1005 Equipment approval, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228976
- Permanent ID
ys:prov:228976@1- SHA-256
d646012d825d77ced088e4327af9d7c83eddc9c80362dbc7420ae2d5e16ecc9f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Electrical equipment that is required to be intrinsically safe or explosion proof under § 154.1010 must be specially approved by the Commandant or listed as intrinsically safe or explosion proof by an independent laboratory that is specially approved by the Commandant (CG-OES), for Class I Division I locations and the Group that is specified in Table 4 for the cargo carried.
(b) Each submerged cargo pump motor installation must be specially approved by the Commandant (CG-OES).
(c) Electrical equipment that must be intrinsically safe to meet § 154.1010 must meet the definition in § 110.15-100(i) of this chapter.
(d) Electrical equipment that must be explosion proof to meet § 154.1010 must meet § 110.15-65(e) of this chapter.
Legislative history