46 CFR 154.1010

§ 154.1010 Electrical equipment in gas-dangerous space or zone.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 154.1010, § 154.1010 Electrical equipment in gas-dangerous space or zone, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228977
Permanent ID
ys:prov:228977@1
SHA-256
89b90c17c7e8cb38713cb7233911099248e3bfc7fe7a6dc8188f0dcda2cb605e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Except as allowed in this section, electrical equipment must not be installed in a gas-dangerous space or zone. (b) Intrinsically safe electrical equipment and wiring may be in a gas-dangerous space or zone. (c) A submerged cargo pump motor may be in a cargo tank if: (1) Low liquid level, motor current, or pump discharge pressure automatically shuts down power to the pump motor if the pump loses suction; (2) There is an audible and visual alarm at the cargo control station that actuates if the motor shuts down under the requirements of paragraph (c)(1) of this section; and (3) There is a lockable circuit breaker or lockable switch that disconnects the power to the motor. (d) A supply cable for a submerged cargo pump motor may be in a hold space. (e) A hold space that has a tank that is not required to have a secondary barrier under § 154.459 may only have: (1) Through runs of cable; (2) Explosion-proof lighting fixtures; (3) Depth sounding devices in gas-tight enclosures; (4) Log devices in gas-tight enclosures; and (5) Impressed current cathodic protection system electrodes in gas-tight enclosures. (f) A space that is separated by a gastight steel boundary from a hold space that has a cargo tank that must have a secondary barrier, under the requirements of § 154.459, may only have: (1) Through runs of cable; (2) Explosion-proof lighting fixtures; (3) Depth sounding devices in gastight enclosures; (4) Log devices in gastight enclosures; (5) Impressed current cathodic protection system electrodes in gastight enclosures; (6) Explosion-proof motors that operate cargo system valves or ballast system valves; and (7) Explosion-proof bells for general alarm systems. (g) A cargo handling room may only have: (1) Explosion-proof lighting fixtures; and (2) Explosion-proof bells for general alarm systems. (h) A space for cargo hose storage may only have: (1) Explosion-proof lighting fixtures; and (2) Through runs of cable. (i) A space that has cargo piping may only have: (1) Explosion-proof lighting fixtures; and (2) Through runs of cable. (j) A gas-dangerous zone on the weather deck may only have: (1) Explosion-proof equipment that is for the operation of the vessel; and (2) Through runs of cable. (k) A space, except those under paragraphs (e) through (j) of this section, that has a direct opening to a gas-dangerous space or zone may only have the electrical equipment allowed in the gas-dangerous space or zone.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.