yourstate.us
46 CFR 154.1210

§ 154.1210 Hold space, void space, cofferdam, and spaces containing cargo piping.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 154.1210, § 154.1210 Hold space, void space, cofferdam, and spaces containing cargo piping, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/228996
Permanent ID
ys:prov:228996@1
SHA-256
67dd30fe3e8a0c7ca6d0f3da3b00ee623d6ad169984a22dd8896a4017b88292f

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each hold space, void space, cofferdam, and spaces containing cargo piping must have: (1) A fixed mechanical ventilation system; or (2) A fixed ducting system that has a portable blower that meets § 154.1205(i) and (j). (b) A portable blower in any personnel access opening must not reduce the area of that opening so that the opening does not meet § 154.340.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.