46 CFR 162.039-3
§ 162.039-3 Requirements.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 162.039-3, § 162.039-3 Requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/229698
- Permanent ID
ys:prov:229698@1- SHA-256
c7554e24c94a37d1a3b63979110f9da9d76eb9c71188406f57b70584486cfa3d
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) In addition to the requirements of this subpart, every semi-portable fire extinguisher must be tested and listed for marine use by a recognized laboratory as defined in 46 CFR 159.001-3, and must comply with the following standards (incorporated by reference, see § 162.039-1), as appropriate:
(1) UL 8;
(2) UL 154;
(3) UL 299;
(4) UL 626;
(5) UL 711; and
(6) UL 2129.
(b) Every semi-portable fire extinguisher must be self-contained; when charged, it must not require any additional source of extinguishing agent or expellant energy for its operation during the time it is being discharged. It must weigh more than 50 pounds, when fully charged.
(c) Every semi-portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use.
(d) Every semi-portable extinguisher may be additionally examined and tested to establish its reliability and effectiveness in accordance with the intent of this specification for a “marine type” semi-portable fire extinguisher when considered necessary by the Coast Guard or by the recognized laboratory.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.