46 CFR 164.009-19
§ 164.009-19 Measurement of moisture and volatile matter content.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 164.009-19, § 164.009-19 Measurement of moisture and volatile matter content, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/229819
- Permanent ID
ys:prov:229819@1- SHA-256
0c911784f169a16dee2b17a3c7e288810387209d4094c6f92235e86274bc02e6
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The measurements described in this section are made to determine the moisture and volatile matter content of a sample.
(b) A specimen cut from the density specimen of a sample is conditioned for at least one week, and for any additional time needed for the specimen to reach a constant weight, in an atmosphere that is 22.8 °C. ±2 °C., and 50 percent ±5 percent relative humidity. The conditioned specimen is then weighed and transferred to a previously weighed wide mouth weighing bottle that has a glass stopper. With the stopper removed, the bottle, stopper, and specimen are heated at 105 °C. ±5 °C. for four hours. After four hours, the stopper is inserted in the bottle and the bottle and sample are cooled and weighed.
(c) The content of moisture and volatile matter is the difference between the two weighings and is reported as a percentage of the weight of the conditioned specimen.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.