yourstate.us
46 CFR 169.553

§ 169.553 Pyrotechnic distress signals.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 169.553, § 169.553 Pyrotechnic distress signals, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230201
Permanent ID
ys:prov:230201@1
SHA-256
fa0f6949fd427b8fdbf6dfb615a347b8f147ece04f192f43a213c1d40fc34890

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) All pyrotechnic distress signals must be of an approved type. (b) Replacement must be made no later than the first inspection for certification or reinspection after the date of expiration. (c) Except as otherwise provided in this section, each vessel must carry the following pyrotechnic distress signals: (1) 6 hand red flare distress signals, and 6 hand orange smoke distress signals; or, (2) 12 hand held rocket propelled parachute red flare distress signals. (d) [Reserved] (e) All pyrotechnic distress signals must be carried near the helm or in a location considered suitable by the Officer in Charge, Marine Inspection. (f) All pyrotechnic distress signals must be stowed in a portable watertight container.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.