yourstate.us
46 CFR 169.666

§ 169.666 Generators and motors.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 169.666, § 169.666 Generators and motors, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230240
Permanent ID
ys:prov:230240@1
SHA-256
09df652ef3e079c0f741f898874e1b16f4526bfceaf549d899da45999218a7a8

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each vessel of more than 65 feet in length having only electrically driven fire and bilge pumps must have two generators. One of these generators must be driven by a means independent of the auxiliary propulsion plant. A generator that is not independent of the auxiliary propulsion plant must meet the requirements of § 111.10-4(c) of this chapter. (b) Each generator and motor must be in a location that is accessible, adequately ventilated, and as dry as practicable. (c) Each generator and motor must be mounted as high as practicable above the bilges to avoid damage by splash and to avoid contact with low lying vapors. (d) Each generator must be protected from overcurrent by a circuit breaker, fuse or an overcurrent relay.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.