yourstate.us
46 CFR 173.085

§ 173.085 General subdivision requirements.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 173.085, § 173.085 General subdivision requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230519
Permanent ID
ys:prov:230519@1
SHA-256
24a2c815dd3216139a37afd66147466e783492cb3615864a95776fdf9f38db75

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each oceanographic vessel must comply with the following: (a) Section 171.085(c)(1), (d) and (g) of this subchapter. (b) Section 171.105 (a) through (g) of this subchapter except that a reduction or elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission of the vessel; and (2) As a result of other design features, the ability of the vessel to withstand side and bottom damage is not reduced. (c) Section 171.106 of this subchapter. (d) Section 171.108 of this subchapter. (e) Section 171.109 of this subchapter. (f) Section 171.111 of this subchapter. (g) Section 171.113 of this subchapter. (h) The collision bulkhead must not be penetrated by more than one pipe that carries liquid to or from the forepeak tank. This pipe must have a screwdown valve that is— (1) Operative from above the bulkhead deck; and (2) Attached to the bulkhead inside the forepeak tank. (i) Section 171.116 (b), (c), and (e) of this subchapter. (j) Section 171.117(c) of this subchapter. (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover. (l) Section 171.118 (b) and (c) of this subchapter. (m) Section 171.122 (a) through (d) and (f) of this subchapter. (n) Section 171.135 of this subchapter. (o) A ventilation duct or forced draft duct may not penetrate a main transverse watertight bulkhead unless— (1) The penetration is watertight; (2) The penetration is located as near the vessel's centerline as possible; and (3) The bottom of the duct is not more than— (i) 18 inches (45.7 cm) below the bulkhead deck; and (ii) 4 feet (121.9 cm) above the final waterline after damage determined in § 173.080.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.