46 CFR 174.195

§ 174.195 Bulkheads in machinery spaces.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 174.195, § 174.195 Bulkheads in machinery spaces, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230554
Permanent ID
ys:prov:230554@1
SHA-256
0749901d1dfb1f9f8390af1dc80e8da46c0e87c12ced9144e0bf09471dc9c4aa

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) The bulkhead in each machinery space of each OSV must be watertight to the bulkhead deck. (b) Each penetration of, and each opening in, a bulkhead in a machinery space must— (1) Be kept as high and as far inboard as practicable; and (2) Except as provided by § 174.210 of this subpart and by paragraph (c) of this section, have means to make it watertight. (c) No penetration of a bulkhead in a machinery space by a ventilation duct need have means to make the bulkhead watertight if— (1) Every part of the duct is at least 760 millimeter (30 inches) from the side of the OSV; and (2) The duct is continuously watertight from the penetration to the main deck. (d) Each penetration of a bulkhead in a machinery space by piping must meet the design requirements for material and pressure in subchapter F of this chapter.

Legislative history