46 CFR 182.425
§ 182.425 Engine exhaust cooling.
United States · 46 CFR — Shipping · Status: effective
Cite this
- Citation
- 46 CFR 182.425, § 182.425 Engine exhaust cooling, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230815
- Permanent ID
ys:prov:230815@1- SHA-256
f980cb49f5c7209d3104a1da67e89aefccae507e5a573bed6e4aa0ad5e304239
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled.
(1) Vertical dry exhaust pipes are permissible if installed in compliance with §§ 177.405(b) and 177.970 of this chapter.
(2) Horizontal dry exhaust pipes are permitted only if:
(i) They do not pass through living or berthing spaces;
(ii) They terminate above the deepest load waterline;
(iii) They are so arranged as to prevent entry of cold water from rough or boarding seas;
(iv) They are constructed of corrosion resisting material at the hull penetration; and
(v) They are installed in compliance with §§ 177.405(b) and 177.970 of this chapter.
(b) The exhaust pipe cooling water system must comply with the requirements of this paragraph.
(1) Water for cooling the exhaust pipe must be obtained from the engine cooling water system or a separate engine driven pump.
(2) Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe.
(3) The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter.
(4) Vertical exhaust pipes must be water-jacketed or suitably insulated as required by § 182.430(g).
(5) When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system.
(6) A suitable hull strainer must be installed in the circulating raw water intake line for the exhaust cooling system.
(c) Engine exhaust cooling system built in accordance with the requirements of ABYC P-1 (incorporated by reference; see 46 CFR 175.600) will be considered as meeting the requirements of this section.