yourstate.us
46 CFR 183.322

§ 183.322 Multiple generators.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 183.322, § 183.322 Multiple generators, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230856
Permanent ID
ys:prov:230856@1
SHA-256
d8fbce6f38d5bc4e1836a67b4604c865e2e1aee443d17d3c64448568144fdbbd

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

When a vessel is equipped with two or more generators to supply ship's service power, the following requirements must be met: (a) Each generator must have an independent prime mover; and (b) The generator circuit breakers must be interlocked to prevent the generators from being simultaneously connected to the switchboard, except for the circuit breakers of a generator operated in parallel with another generator when the installation meets §§ 111.12-11(f) and 111.30-25(d) in subchapter J of this chapter.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.