§ 183.370 General grounding requirements.

United States · 46 CFR — Shipping · Status: effective

Get this as JSONEmbed this
Cite this
Citation
46 CFR 183.370, § 183.370 General grounding requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/230864
Permanent ID
ys:prov:230864@1
SHA-256
175c7ee9a416f5298c9dc3ce559ad4523c535834f195d2521c83a4d145be016a

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) A vessel's hull must not carry current as a conductor except for the following systems: (1) Impressed current cathodic protection systems; or (2) Battery systems for engine starting. (b) Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor in the portable cord. (c) Each nonmetallic mast and top mast must have a lightning ground conductor.