W. Va. Code § 22A-2-41
Bonding track used as power conductor
West Virginia · West Virginia Code Chapter 22A — Miners' Health, Safety and Training · Status: effective
Cite this
- Citation
- W. Va. Code § 22A-2-41, Bonding track used as power conductor, West Virginia, version 1 as recorded 2026-10-03, yourstate.us, https://yourstate.us/provision/2376306
- Permanent ID
ys:prov:2376306@1- SHA-256
06f5efeb9b48a5de9baa46528f9c033fbdbcf091738aae154904b3f88e962d4c
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Where track is used as a power conductor, rails and switches on main entries shall be bonded and cross-bonded in such manner as to assure adequate return. At least one rail on secondary track-haulage roads shall be welded or bonded at every joint, and cross bonds shall be installed at intervals of not more than two hundred feet: Provided, however, That rail joints in such secondary haulage roads need not be bonded where a copper feeder adequate in size parallels the track and is electrically connected thereto at intervals of not more than two hundred feet by cross bonds.