49 CFR 173.4
§ 173.4 Small quantities for highway and rail.
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 173.4, § 173.4 Small quantities for highway and rail, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/255897
- Permanent ID
ys:prov:255897@1- SHA-256
b6ca6e46af30b4971e389120440fd68301fde112e4df27c7c78163dad1bcdea4
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) When transported domestically by highway or rail in conformance with this section, quantities of Division 2.2 (except aerosols with no subsidiary hazard), Class 3, Division 4.1, Division 4.2 (PG II and III), Division 4.3 (PG II and III), Division 5.1, Division 5.2, Division 6.1, Class 7, Class 8, and Class 9 materials are not subject to any other requirements when—
(1) The maximum quantity of material per inner receptacle or article is limited to—
(i) Thirty (30) mL (1 ounce) for authorized liquids, other than Division 6.1, Packing Group I, Hazard Zone A or B materials;
(ii) Thirty (30) g (1 ounce) for authorized solid materials;
(iii) One (1) g (0.04 ounce) for authorized materials meeting the definition of a Division 6.1, Packing Group I, Hazard Zone A or B material; and
(iv) [Reserved]
(v) Thirty (30) mL water capacity (1.8 cubic inches) for authorized Division 2.2 materials.
(2) With the exception of temperature sensing devices, each inner receptacle:
(i) Is not liquid-full at 55 °C (131 °F), and
(ii) Is constructed of plastic having a minimum thickness of no less than 0.2 mm (0.008 inch), or earthenware, glass, or metal;
(3) Each inner receptacle with a removable closure has its closure held securely in place with wire, tape, or other positive means;
(4) Unless equivalent cushioning and absorbent material surrounds the inside packaging, each inner receptacle is securely packed in an inside packaging with cushioning and absorbent material that:
(i) Will not react chemically with the material, and
(ii) Is capable of absorbing the entire contents (if a liquid) of the receptacle;
(5) The inside packaging is securely packed in a strong outer packaging;
(6) The completed package, as demonstrated by prototype testing, is capable of sustaining—
(i) Each of the following free drops made from a height of 1.8 m (5.9 feet) directly onto a solid unyielding surface without breakage or leakage from any inner receptacle and without a substantial reduction in the effectiveness of the package:
(A) One drop flat on bottom;
(B) One drop flat on top;
(C) One drop flat on the long side;
(D) One drop flat on the short side; and
(E) One drop on a corner at the junction of three intersecting edges; and
(ii) A compressive load as specified in § 178.606(c) of this subchapter.
Each of the tests in paragraph (a)(6) of this section may be performed on a different but identical package; i.e., all tests need not be performed on the same package.
(7) Placement of the material in the package or packing different materials in the package does not result in a violation of § 173.21;
(8) The gross mass of the completed package does not exceed 29 kg (64 pounds);
(9) The package is not opened or otherwise altered until it is no longer in commerce; and
(10) The shipper certifies conformance with this section by marking the outside of the package with the statement “This package conforms to 49 CFR 173.4 for domestic highway or rail transport only.”
(b) A package containing a Class 7 (radioactive) material also must conform to the requirements of § 173.421(a) through (e), § 173.424(a) through (g), or § 173.426(a) through (c) as applicable.
(c) Packages which contain a Class 2 (other than those authorized in paragraph (a) of this section), Division 4.2 (PG I), or Division 4.3 (PG I) material conforming to paragraphs (a)(1) through (10) of this section may be offered for transportation or transported if approved by the Associate Administrator.
(d) Lithium batteries and cells are not eligible for the exceptions provided in this section.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.