49 CFR 175.702
§ 175.702 Separation distance requirements for packages containing Class 7 (radioactive) materials in cargo aircraft.
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 175.702, § 175.702 Separation distance requirements for packages containing Class 7 (radioactive) materials in cargo aircraft, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/256233
- Permanent ID
ys:prov:256233@1- SHA-256
453f2d1d1af979030eee12beeffb4343df623b52781bd0a3df1bf6f0c4f8512a
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) No person may carry in a cargo aircraft any package required by § 172.403 of this subchapter to be labeled Radioactive Yellow-II or Radioactive Yellow-III unless:
(1) The total transport index for all packages does not exceed 50.0 and the packages are carried in accordance with § 175.701(a); or
(2) The total transport index for all packages exceeds 50.0; and
(i) The separation distance between the surfaces of the radioactive materials packages, overpacks or freight containers and any space occupied by live animals is at least 0.5 m (20 inches) for journeys not exceeding 24 hours and at least 1.0 m (39 inches) for journeys longer than 24 hours; and
(ii) The minimum separation distances between the radioactive material and any areas occupied by persons that are specified in the following table are maintained:
(b) In addition to the limits on combined criticality safety indexes stated in § 175.700(b),
(1) The criticality safety index of any single group of packages must not exceed 50.0 (as used in this section, the term “group of packages” means packages that are separated from each other in an aircraft by a distance of 6 m (20 feet) or less); and
(2) Each group of packages must be separated from every other group in the aircraft by not less than 6 m (20 feet), measured from the outer surface of each group.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.