§ 179.201-8 Sampling device and thermometer well.
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 179.201-8, § 179.201-8 Sampling device and thermometer well, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/256759
- Permanent ID
ys:prov:256759@1- SHA-256
b12f4ad1b18b9bb026cd4a10be9d91c1c5dbb14161add00035004b780ab888be
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Sampling valve and thermometer well are not specification requirements. When used, they must be of approved design, made of metal not subject to rapid deterioration by lading, and must withstand a pressure of 100 psig without leakage. Interior pipes of the sampling valve must be equipped with excess flow valves of an approved design. Interior pipe of thermometer well must be closed by an approved valve attached close to fitting where it passes through the tank and closed by a screw plug. Other approved arrangements that permit testing thermometer well for leaks without complete removal of the closure may be used.