49 CFR 192.353

§ 192.353 Customer meters and regulators: Location.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 192.353, § 192.353 Customer meters and regulators: Location, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257129
Permanent ID
ys:prov:257129@1
SHA-256
67a99192b342a0f8d095cb5396745a367abd121733dce6f0adb573394f1ef875

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each meter and service regulator, whether inside or outside a building, must be installed in a readily accessible location and be protected from corrosion and other damage, including, if installed outside a building, vehicular damage that may be anticipated. However, the upstream regulator in a series may be buried. (b) Each service regulator installed within a building must be located as near as practical to the point of service line entrance. (c) Each meter installed within a building must be located in a ventilated place and not less than 3 feet (914 millimeters) from any source of ignition or any source of heat which might damage the meter. (d) Where feasible, the upstream regulator in a series must be located outside the building, unless it is located in a separate metering or regulating building.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.