§ 192.457 External corrosion control: Buried or submerged pipelines installed before August 1, 1971.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 192.457, § 192.457 External corrosion control: Buried or submerged pipelines installed before August 1, 1971, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257152
Permanent ID
ys:prov:257152@1
SHA-256
df50f0d3aa565fcccdc20c3b2ed6b2b59cfe1f0b17b8c8522fed5d8cf4a723f0

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Except for buried piping at compressor, regulator, and measuring stations, each buried or submerged transmission line installed before August 1, 1971, that has an effective external coating must be cathodically protected along the entire area that is effectively coated, in accordance with this subpart. For the purposes of this subpart, a pipeline does not have an effective external coating if its cathodic protection current requirements are substantially the same as if it were bare. The operator shall make tests to determine the cathodic protection current requirements. (b) Except for cast iron or ductile iron, each of the following buried or submerged pipelines installed before August 1, 1971, must be cathodically protected in accordance with this subpart in areas in which active corrosion is found: (1) Bare or ineffectively coated transmission lines. (2) Bare or coated pipes at compressor, regulator, and measuring stations. (3) Bare or coated distribution lines.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.