§ 192.476 Internal corrosion control: Design and construction of transmission line.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 192.476, § 192.476 Internal corrosion control: Design and construction of transmission line, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257162
Permanent ID
ys:prov:257162@1
SHA-256
6112139adb802888ade2716ca871c6cb6dfab3da9e6cb79a123d3e88c022ff2b

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Design and construction. Except as provided in paragraph (b) of this section, each new transmission line and each replacement of line pipe, valve, fitting, or other line component in a transmission line must have features incorporated into its design and construction to reduce the risk of internal corrosion. At a minimum, unless it is impracticable or unnecessary to do so, each new transmission line or replacement of line pipe, valve, fitting, or other line component in a transmission line must: (1) Be configured to reduce the risk that liquids will collect in the line; (2) Have effective liquid removal features whenever the configuration would allow liquids to collect; and (3) Allow use of devices for monitoring internal corrosion at locations with significant potential for internal corrosion. (b) Exceptions to applicability. The design and construction requirements of paragraph (a) of this section do not apply to the following: (1) Offshore pipeline; and (2) Pipeline installed or line pipe, valve, fitting or other line component replaced before May 23, 2007. (c) Change to existing transmission line. When an operator changes the configuration of a transmission line, the operator must evaluate the impact of the change on internal corrosion risk to the downstream portion of an existing onshore transmission line and provide for removal of liquids and monitoring of internal corrosion as appropriate. (d) Records. An operator must maintain records demonstrating compliance with this section. Provided the records show why incorporating design features addressing paragraph (a)(1), (a)(2), or (a)(3) of this section is impracticable or unnecessary, an operator may fulfill this requirement through written procedures supported by as-built drawings or other construction records.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.