49 CFR 192.740
§ 192.740 Pressure regulating, limiting, and overpressure protection—Individual service lines directly connected to regulated gathering or transmission pipelines.
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 192.740, § 192.740 Pressure regulating, limiting, and overpressure protection—Individual service lines directly connected to regulated gathering or transmission pipelines, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257241
- Permanent ID
ys:prov:257241@1- SHA-256
306fe5434b0d813bcae7b7cc892438086655d749781742c770c775cf3b31d427
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) This section applies, except as provided in paragraph (c) of this section, to any service line directly connected to a transmission pipeline or regulated gathering pipeline as determined in § 192.8 that is not operated as part of a distribution system.
(b) Each pressure regulating or limiting device, relief device (except rupture discs), automatic shutoff device, and associated equipment must be inspected and tested at least once every 3 calendar years, not exceeding 39 months, to determine that it is:
(1) In good mechanical condition;
(2) Adequate from the standpoint of capacity and reliability of operation for the service in which it is employed;
(3) Set to control or relieve at the correct pressure consistent with the pressure limits of § 192.197; and to limit the pressure on the inlet of the service regulator to 60 psi (414 kPa) gauge or less in case the upstream regulator fails to function properly; and
(4) Properly installed and protected from dirt, liquids, or other conditions that might prevent proper operation.
(c) This section does not apply to equipment installed on:
(1) A service line that only serves engines that power irrigation pumps;
(2) A service line included in a distribution integrity management plan meeting the requirements of subpart P of this part; or
(3) A service line directly connected to either a production or gathering pipeline other than a regulated gathering line as determined in § 192.8 of this part.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.