49 CFR 195.585

§ 195.585 What must I do to correct corroded pipe?

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 195.585, § 195.585 What must I do to correct corroded pipe?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257580
Permanent ID
ys:prov:257580@1
SHA-256
36246f4b72d9bc13f4df3f645351631955b07938a90c176904630433db6d8239

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) General corrosion. If you find pipe so generally corroded that the remaining wall thickness is less than that required for the maximum operating pressure of the pipeline, you must replace the pipe. However, you need not replace the pipe if you— (1) Reduce the maximum operating pressure commensurate with the strength of the pipe needed for serviceability based on actual remaining wall thickness; or (2) Repair the pipe by a method that reliable engineering tests and analyses show can permanently restore the serviceability of the pipe. (b) Localized corrosion pitting. If you find pipe that has localized corrosion pitting to a degree that leakage might result, you must replace or repair the pipe, unless you reduce the maximum operating pressure commensurate with the strength of the pipe based on actual remaining wall thickness in the pits.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.