49 CFR 195.587
§ 195.587 What methods are available to determine the strength of corroded pipe?
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 195.587, § 195.587 What methods are available to determine the strength of corroded pipe?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/257581
- Permanent ID
ys:prov:257581@1- SHA-256
b1d13b3863282ebfbac1dd417eb73fba51254e56ab554d7410ca1ce12c328ad3
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Under § 195.585, you may use the procedure in ASME/ANSI B31G (incorporated by reference, see § 195.3) or in PRCI PR-3-805 (R-STRENG) (incorporated by reference, see § 195.3) to determine the strength of corroded pipe based on actual remaining wall thickness. These procedures apply to corroded regions that do not penetrate the pipe wall, subject to the limitations set out in the respective procedures.
Legislative history