yourstate.us
49 CFR 230.38

§ 230.38 Telltale holes.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 230.38, § 230.38 Telltale holes, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/258649
Permanent ID
ys:prov:258649@1
SHA-256
aed340d0bb6d173aef0e6be55dfd3cec9ec435966b2513a12516aec164c5eb40

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Staybolts less than 8 inches long. All staybolts shorter than 8 inches, except flexible bolts, shall have telltale holes 3/16 inch to 7/32 inch diameter and at least 1 1/4 inches deep in the outer end. (b) Reduced body staybolts. On reduced body staybolts, the telltale hole shall extend beyond the fillet and into the reduced section of the staybolt. Staybolts may have through telltale holes. (c) Telltale holes kept open. All telltale holes, except as provided for in § 230.41, must be kept open at all times.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.