49 CFR 230.51
§ 230.51 Number and location.
United States · 49 CFR — Transportation · Status: effective
Cite this
- Citation
- 49 CFR 230.51, § 230.51 Number and location, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/258662
- Permanent ID
ys:prov:258662@1- SHA-256
b6d3adb228e26f4590e965f3b03a842d966f0ed0f03ca1ee4e2270a1fd896c91
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Every boiler shall be equipped with at least two water glasses. The lowest reading of the water glasses shall not be less than 3 inches above the highest part of the crown sheet. If gauge cocks are used, the reading of the lowest gauge cock shall not be less than 3 inches above the highest part of the crown sheet.