§ 230.60 Time of washing.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 230.60, § 230.60 Time of washing, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/258671
Permanent ID
ys:prov:258671@1
SHA-256
b27a07c2edd89a2b9fd9fc81fe09f4902a95cbd3795d62f11941d9da75e11ee5

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Frequency of washing. All boilers shall thoroughly be washed as often as the water conditions require, but not less frequently than at each 31 service day inspection. The date of the boiler wash shall be noted on the FRA Form No. 1 or FRA Form No. 3. (See appendix B of this part.) (b) Plug removal. All washout plugs, arch tube plugs, thermic siphon plugs, circulator plugs and water bar plugs must be removed whenever locomotive boilers are washed. (c) Plug maintenance. All washout plugs, washout plug sleeves and threaded openings shall be maintained in a safe and suitable condition for service and shall be examined for defects each time the plugs are removed. (d) Fusible plugs cleaned. Fusible plugs shall be cleaned in accordance with § 230.59.