49 CFR 236.56

§ 236.56 Shunting sensitivity.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 236.56, § 236.56 Shunting sensitivity, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/258967
Permanent ID
ys:prov:258967@1
SHA-256
a8a96996d4e5b4a01dd4109fed1bfb34824a65c31c733291edde89bc025b893a

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each track circuit controlling home signal or approach locking shall be so maintained that track relay is in deenergized position, or device that functions as a track relay shall be in its most restrictive state if, when track circuit is dry, a shunt of 0.06 ohm resistance is connected across the track rails of the circuit, including fouling sections of turnouts.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.