§ 236.57 Shunt and fouling wires.

United States · 49 CFR — Transportation · Status: effective

Get this as JSONEmbed this
Cite this
Citation
49 CFR 236.57, § 236.57 Shunt and fouling wires, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/258968
Permanent ID
ys:prov:258968@1
SHA-256
6bfde04619cf83bbe2c38f9a750540a9e2f3b19619d2f5b5b200b330dd41d23e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Except as provided in paragraph (b) of this section, shunt wires and fouling wires hereafter installed or replaced shall consist of at least two discrete conductors, and each shall be of sufficient conductivity and maintained in such condition that the track relay will be in deenergized position, or device that functions as a track relay will be in its most restrictive state, when the circuit is shunted. (b) This rule does not apply to shunt wires where track or control circuit is opened by the switch circuit controller.