7 CFR 3300.10
§ 3300.10 Measurement of the K-coefficient of an insulated body.
United States · 7 CFR — Agriculture · Status: effective
Cite this
- Citation
- 7 CFR 3300.10, § 3300.10 Measurement of the K-coefficient of an insulated body, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/29755
- Permanent ID
ys:prov:29755@1- SHA-256
d2abfc18ab2a598191d55ea3fdec5f013022987ba492d5c886ab3919f1187a2c
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The K-coefficient shall be measured according to the procedures in ATP, Annex 1, Appendix 2, paragraphs 1-28, and the following shall apply:
(a) The internal heating method shall be used.
(b) In ATP, Annex 1, Appendix 2, paragraph 8, last line, “about + 20 °C for the mean temperature of the walls of the body shall be interpreted to mean between +19 °C (+66 °F) and 21 °C (+70 °F).
(c) A report of each test shall be completed on a form corresponding to the pertinent test report model prescribed in ATP, Annex 1, Appendix 2. Report forms may be obtained by a request to the ATP manager.