§ 113.29 Determination of moisture content in desiccated biological products.

United States · 9 CFR — Animals and Animal Products · Status: effective

Get this as JSONEmbed this
Cite this
Citation
9 CFR 113.29, § 113.29 Determination of moisture content in desiccated biological products, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/33927
Permanent ID
ys:prov:33927@1
SHA-256
0855ea6bd2d6a3f92041069b9636bb968b28c6ec70304411c93a845586b8011e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Methods provided in this section must be used when a determination of moisture content in desiccated biological products is prescribed in an applicable Standard Requirement or in the filed Outline of Production for the product. Firms currently using methods other than those provided in this section for determining the moisture content in desiccated biological products have until November 5, 2004 to update their Outlines of Production to be in compliance with this requirement. (a) Final container samples of completed product shall be tested. The weight loss of the sample due to drying in a vacuum oven shall be determined. All procedures should be performed in an environment with a relative humidity less than 45 percent. The equipment necessary to perform the test is as follows: (1) Cylindrical weighing bottles with airtight glass stoppers. (2) Vacuum oven equipped with validated thermometer and thermostat. A suitable air-drying device should be attached to the inlet valve. (3) Balance, accurate to 0.1 mg (rated precision ±0.01mg). (4) Desiccator jar equipped with phosphorous pentoxide, silica gel, or equivalent. (5) Desiccated vaccine in original sealed vial. Sample and control should be kept at room temperature in their original airtight containers until use. (b) Test procedure: (1) Thoroughly cleaned and labeled sample-weighing bottles with stoppers should be allowed to dry at 60 ±3 °C under vacuum at less than 2.5 kPa. (i) Transfer hot bottles and stoppers into the desiccator and allow to cool to room temperature. (ii) After bottles have cooled, insert stoppers and weigh and record the weights of the bottles as “A.” (iii) Return weighing bottles to the desiccator. (2) Remove the sample container seal. (i) Using a spatula, break up the sample plug and transfer the required amount of sample to the previously tared weighing bottle. (ii) Insert the stopper and weigh and record the weights of the weighing bottles as “B.” (3) Place the weighing bottle with the stopper at an angle in the vacuum oven. Set the vacuum to <2.5 kPa and the temperature to 60 ±3 °C. (4) After a minimum of 3 hours of drying time, turn off the vacuum pump and allow dry air to bleed into the oven until the pressure inside the oven is equalized with the prevailing atmospheric pressure. (5) While the bottle is still warm, replace the stopper in its normal position and transfer the weighing bottle to the desiccator. (i) Allow a minimum of 2 hours for the weighing bottle to cool to room temperature or for its weight to reach equilibrium. (ii) Weigh, and record the weight as “C.” (6) Calculate the percentage of moisture in the original sample as follows: (7) The results are considered satisfactory if the percentage of residual moisture is less than or equal to the manufacturer's specification.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.