yourstate.us
10 CFR 20.1202

§ 20.1202 Compliance with requirements for summation of external and internal doses.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 20.1202, § 20.1202 Compliance with requirements for summation of external and internal doses, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/36493
Permanent ID
ys:prov:36493@1
SHA-256
907cb2d806b2c0b1420fe6a40720cb9631f360a0fb0dc182b97322dd6e0554a0

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) If the licensee is required to monitor under both §§ 20.1502 (a) and (b), the licensee shall demonstrate compliance with the dose limits by summing external and internal doses. If the licensee is required to monitor only under § 20.1502(a) or only under § 20.1502(b), then summation is not required to demonstrate compliance with the dose limits. The licensee may demonstrate compliance with the requirements for summation of external and internal doses by meeting one of the conditions specified in paragraph (b) of this section and the conditions in paragraphs (c) and (d) of this section. The dose equivalents for the lens of the eye, the skin, and the extremities are not included in the summation, but are subject to separate limits.) (b) Intake by inhalation. If the only intake of radionuclides is by inhalation, the total effective dose equivalent limit is not exceeded if the sum of the deep-dose equivalent divided by the total effective dose equivalent limit, and one of the following, does not exceed unity: (1) The sum of the fractions of the inhalation ALI for each radionuclide, or (2) The total number of derived air concentration-hours (DAC-hours) for all radionuclides divided by 2,000, or (3) The sum of the calculated committed effective dose equivalents to all significantly irradiated 1 organs or tissues (T) calculated from bioassay data using appropriate biological models and expressed as a fraction of the annual limit. 1 An organ or tissue is deemed to be significantly irradiated if, for that organ or tissue, the product of the weighting factor, wT, and the committed dose equivalent, HT,50, per unit intake is greater than 10 percent of the maximum weighted value of HT,50, (i.e., WT HT,50) per unit intake for any organ or tissue. (c) Intake by oral ingestion. If the occupationally exposed individual also receives an intake of radionuclides by oral ingestion greater than 10 percent of the applicable oral ALI, the licensee shall account for this intake and include it in demonstrating compliance with the limits. (d) Intake through wounds or absorption through skin. The licensee shall evaluate and, to the extent practical, account for intakes through wounds or skin absorption. The intake through intact skin has been included in the calculation of DAC for hydrogen-3 and does not need to be further evaluated.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.