yourstate.us
10 CFR 36.31

§ 36.31 Control of source movement.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 36.31, § 36.31 Control of source movement, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/37072
Permanent ID
ys:prov:37072@1
SHA-256
ede019872400878fcd45b30901152545e8ce54854ae72071d2d3af7f7658e4bb

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) The mechanism that moves the sources of a panoramic irradiator must require a key to actuate. Actuation of the mechanism must cause an audible signal to indicate that the sources are leaving the shielded position. Only one key may be in use at any time, and only operators or facility management may possess it. The key must be attached to a portable radiation survey meter by a chain or cable. The lock for source control must be designed so that the key may not be removed if the sources are in an unshielded position. The door to the radiation room must require the same key. (b) The console of a panoramic irradiator must have a source position indicator that indicates when the sources are in the fully shielded position, when they are in transit, and when the sources are exposed. (c) The control console of a panoramic irradiator must have a control that promptly returns the sources to the shielded position. (d) Each control for a panoramic irradiator must be clearly marked as to its function.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.