yourstate.us
10 CFR 50.46a

§ 50.46a Acceptance criteria for reactor coolant system venting systems.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 50.46a, § 50.46a Acceptance criteria for reactor coolant system venting systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/37272
Permanent ID
ys:prov:37272@1
SHA-256
1072275fce529df4e22f7af649598e12405b47aa27065bb6d308bad4ed70a81f

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each nuclear power reactor must be provided with high point vents for the reactor coolant system, for the reactor vessel head, and for other systems required to maintain adequate core cooling if the accumulation of noncondensible gases would cause the loss of function of these systems. High point vents are not required for the tubes in U-tube steam generators. Acceptable venting systems must meet the following criteria: (a) The high point vents must be remotely operated from the control room. (b) The design of the vents and associated controls, instruments and power sources must conform to appendix A and appendix B of this part. (c) The vent system must be designed to ensure that: (1) The vents will perform their safety functions; and (2) There would not be inadvertent or irreversible actuation of a vent.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.