10 CFR 71.61

§ 71.61 Special requirements for Type B packages containing more than 10

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 71.61, § 71.61 Special requirements for Type B packages containing more than 10, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/38240
Permanent ID
ys:prov:38240@1
SHA-256
eabf60566a6340ac3c39115125c21803b5bd47bd6defa99b70756f96fe860888

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

A Type B package containing more than 10 5A2 must be designed so that its undamaged containment system can withstand an external water pressure of 2 MPa (290 psi) for a period of not less than 1 hour without collapse, buckling, or inleakage of water.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.