10 CFR 71.93
§ 71.93 Inspection and tests.
United States · 10 CFR — Energy · Status: effective
Cite this
- Citation
- 10 CFR 71.93, § 71.93 Inspection and tests, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/38259
- Permanent ID
ys:prov:38259@1- SHA-256
5cddeb7b6c3e7a845ca4c7d11b77aef8a599963da4b233e176fd68e021e2e6ca
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The licensee, certificate holder, and applicant for a CoC shall permit the Commission, at all reasonable times, to inspect the licensed material, packaging, premises, and facilities in which the licensed material or packaging is used, provided, constructed, fabricated, tested, stored, or shipped.
(b) The licensee, certificate holder, and applicant for a CoC shall perform, and permit the Commission to perform, any tests the Commission deems necessary or appropriate for the administration of the regulations in this chapter.
(c) The certificate holder and applicant for a CoC shall notify the NRC, in accordance with § 71.1, 45 days in advance of starting fabrication of the first packaging under a CoC. This paragraph applies to any packaging used for the shipment of licensed material which has either—
(1) A decay heat load in excess of 5 kW; or
(2) A maximum normal operating pressure in excess of 103 kPa (15 lbf/in 2) gauge.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.