10 CFR 429.21
§ 429.21 Residential clothes dryers.
United States · 10 CFR — Energy · Status: effective
Cite this
- Citation
- 10 CFR 429.21, § 429.21 Residential clothes dryers, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39258
- Permanent ID
ys:prov:39258@1- SHA-256
5d7f07300042d7f3c8b58cbf22a8deb1d92e7cfbe010b1704d59a9307236dfd0
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 are applicable to clothes dryers; and
(2) For each basic model of clothes dryers a sample of sufficient size shall be randomly selected and tested to ensure that—
(i) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(A) The mean of the sample, where:
Or,
(B) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:
and
(ii) Any represented value of the energy factor, combined energy factor, or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(A) The mean of the sample, where:
Or,
(B) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:
(3) The capacity of a basic model reported in accordance with paragraph (b)(2) of this section shall be the mean of the capacities measured for each tested unit of the basic model.
(b) Certification reports.
(1) The requirements of § 429.12 are applicable to clothes dryers; and
(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: When using appendix D1 to subpart B of part 430 of this chapter, the combined energy factor in pounds per kilowatt hours (lb/kWh), the capacity in cubic feet (cu ft), the voltage in volts (V) (for electric dryers only), an indication if the dryer has automatic termination controls, and the hourly Btu rating of the burner (for gas dryers only); when using appendix D2 to subpart B of part 430, the combined energy factor in pounds per kilowatt hours (lb/kWh), the capacity in cubic feet (cu ft), the voltage in volts (V) (for electric dryers only), an indication if the dryer has automatic termination controls, the hourly Btu rating of the burner (for gas dryers only), and a list of the cycle setting selections for the energy test cycle as recorded in section 3.4.7 of appendix D2 to subpart B of part 430.
(c) Reported values. Values reported pursuant to this section must be rounded as follows: CEF to the nearest 0.01 lb/kWh, capacity to the nearest 0.1 cu ft, voltage to the nearest V, and hourly Btu rating to the nearest Btu.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.