10 CFR 429.27
§ 429.27 General service fluorescent lamps.
United States · 10 CFR — Energy · Status: effective
Cite this
- Citation
- 10 CFR 429.27, § 429.27 General service fluorescent lamps, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39264
- Permanent ID
ys:prov:39264@1- SHA-256
aac854a619dbb85b58284941e113dae5799c1abde5869b7ff0a1387217fce3bd
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Prior to February 17, 2023, certification reports must be submitted as required either in this section or 10 CFR 429.27 as it appears in the 10 CFR parts 200 through 499 edition revised as of January 1, 2022. On or after February 17, 2023, certification reports must be submitted as required in this section.
(a) Determination of Represented Value. Each manufacturer must determine represented values, which include certified ratings, for each basic model by testing, in accordance with the following sampling provisions.
(1) Units to be tested.
(i) When testing, use a sample comprised of production units. The same sample of units must be tested and used as the basis for representations for rated wattage, average lamp efficacy, color rendering index (CRI), and correlated color temperature (CCT).
(ii) For each basic model, randomly select and test a sample of sufficient size, but not less than 10 units, to ensure that represented values of average lamp efficacy are less than or equal to the lower of:
(A) The arithmetic mean of the sample: or,
(B) The lower 95 percent confidence limit (LCL) of the true mean divided by .97, where:
(2) Any represented values of measures of energy efficiency or energy consumption for all individual models represented by a given basic model must be the same.
(3) Represented values of CCT, CRI and rated wattage must be equal to the arithmetic mean of the sample.
(b) Certification reports.
(1) The requirements of § 429.12 apply to general service fluorescent lamps; and
(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: The testing laboratory's ILAC accreditation body's identification number or other approved identification assigned by the ILAC accreditation body, average lamp efficacy in lumens per watt (lm/W), rated wattage in watts (W), CCT in Kelvin (K), and CRI.
(c) Rounding Requirements.
(1) Round rated wattage to the nearest tenth of a watt.
(2) Round average lamp efficacy to the nearest tenth of a lumen per watt.
(3) Round CCT to the nearest 100 kelvin (K).
(4) Round CRI to the nearest whole number.
Legislative history