10 CFR 429.51
§ 429.51 Commercial pre-rinse spray valves.
United States · 10 CFR — Energy · Status: effective
Cite this
- Citation
- 10 CFR 429.51, § 429.51 Commercial pre-rinse spray valves, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39288
- Permanent ID
ys:prov:39288@1- SHA-256
b036d2d58e024e99c56c696c404ff202941955eb236c8ca734b3965c0356f9f4
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 apply to commercial prerinse spray valves; and
(2) For each basic model of commercial prerinse spray valve, a sample of sufficient size must be randomly selected and tested to ensure that any represented value of flow rate must be greater than or equal to the higher of:
(i) The mean of the sample, where:
(ii) The upper 95-percent confidence limit (UCL) of the true mean divided by 1.10, where:
(b) Certification reports.
(1) The requirements of § 429.12 are applicable to commercial prerinse spray valves; and
(2) Pursuant to § 429.12(b)(13), a certification report must include the following public product-specific information: The flow rate, in gallons per minute (gpm), rounded to the nearest 0.01 gpm, and the corresponding spray force, in ounce-force (ozf), rounded to the nearest 0.1 ozf.