§ 429.58 Furnace fans.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 429.58, § 429.58 Furnace fans, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39295
Permanent ID
ys:prov:39295@1
SHA-256
7e260d0a09b3db760cc1c2e22ebe09684da77f95b978b108e971d64519e2c0f8

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to furnace fans; and (2) For each basic model of furnace fan within the scope of appendix AA of subpart B of part 430, a sample of sufficient size shall be randomly selected and tested to ensure that any represented value of fan energy rating (FER), rounded to the nearest integer, shall be greater than or equal to the higher of: (i) The mean of the sample, where: And, x is the sample mean; n is the number of samples; and xi is the measured value for the i th sample; Or, (ii) The upper 90 percent confidence limit (UCL) of the true mean divided by 1.05, where: And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the t statistic for a 90% one-tailed confidence interval with n-1 degrees of freedom (from Appendix A). (b) Certification reports. (1) The requirements of § 429.12 are applicable to residential furnace fans; and (2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: The fan energy rating (FER) in watts per thousand cubic feet per minute (W/1000 cfm); the calculated maximum airflow at the reference system external static pressure (ESP) in cubic feet per minute (cfm); the control system configuration for achieving the heating and constant-circulation airflow-control settings required for determining FER as specified in the furnace fan test procedure (10 CFR part 430, subpart B, appendix AA); the measured steady-state gas, oil, or electric heat input rate (QIN) in the heating setting required for determining FER; and for modular blowers, the manufacturer and model number of the electric heat resistance kit with which it is equipped for certification testing.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.