§ 429.76 Portable electric spas.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 429.76, § 429.76 Portable electric spas, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39313
Permanent ID
ys:prov:39313@1
SHA-256
195384dbcb8c2aa47bd7fb47b100ab3ed728379781ded8c5aa16314d124482e6

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Determination of represented values. Manufacturers must determine the represented values for each basic model of portable electric spas by testing in conjunction with the following provisions. (1) For spa covers: (i) If a basic model is distributed in commerce with multiple covers designated by the spa manufacturer for use with the basic model, a manufacturer must determine all represented values for that basic model based on the cover that results in the highest standby loss, except that the manufacturer may choose to identify specific individual combinations of spa and cover as additional basic models. (ii) If a basic model is distributed in commerce with no cover designated by the spa manufacturer for use with the basic model, a manufacturer must determine all represented values for that basic model by testing as specified in section 3.1.5.2 of appendix GG to subpart B of this part. (2) The sampling requirements of § 429.11 are applicable to portable electric spas; and (3) For each basic model of portable electric spas, a sample of sufficient size must be randomly selected and tested to ensure that any representation of standby loss or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of: (i) The mean of the sample, where: and x is the sample mean, n is the number of samples, and xi is the i th sample; or, (ii) The upper 95 percent confidence limit (UCL) of the true mean divided by 1.05, where: and x is the sample mean, s is the sample standard deviation, n is the number of samples, and t0.95 is the t statistic for a 95 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix A of subpart B of part 429). (4) The represented value of standby loss must be a whole number of watts. (5) The represented value of fill volume of a basic model must be a whole number of gallons that is within 5 gallons of the mean of the fill volumes measured for the units in the sample selected as described in paragraph (a)(3) of this section. (b) [Reserved]

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.