yourstate.us
10 CFR — Energy

Appendix B to Subpart C of Part 429—Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR — Energy, Appendix B to Subpart C of Part 429—Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39344
Permanent ID
ys:prov:39344@1
SHA-256
5d6595d867645bf3d3c71faf462403036fada2dff85dfe18456b7dd2ac57f147

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

The Department will determine compliance as follows: (a) The first sample size (n1) must be four or more units, except as provided by § 429.57(e)(1)(ii). (b) Compute the mean of the measured energy performance (x1) for all tests as follows: where xi is the measured energy efficiency or consumption from test i, and n1 is the total number of tests. (c) Compute the standard deviation (s1) of the measured energy performance from the n1 tests as follows: (d) Compute the standard error (sx1) of the measured energy performance from the n1 tests as follows: (e)(1) For an energy efficiency standard (EES), determine the appropriate lower control limit (LCL1) according to: And use whichever is greater. Where EES is the energy efficiency standard and t is a statistic based on a 97.5 percent, one-sided confidence limit and a sample size of n1. (2) For an energy consumption standard (ECS), determine the appropriate upper control limit (UCL1) according to: And use whichever is less, where ECS is the energy consumption standard and t is a statistic based on a 97.5 percent, one-sided confidence limit and a sample size of n1. (f)(1) Compare the sample mean to the control limit. (i) The basic model is in compliance and testing is at an end if: (A) For an energy or water efficiency standard, the sample mean is equal to or greater than the lower control limit, or (B) For an energy or water consumption standard, the sample mean is equal to or less than the upper control limit.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.